NO HOT WATER? DO THIS TO FIX YOUR WATER HEATER

6/13/2020

0 Comments

 
water heater no hot water
In today’s blog post, we found Pat from Pros DIY and he had some great tips on how to troubleshoot your water heater if it’s not giving hot water. 

And we agree with him completely. Hope you guys will enjoy and find these tips helpful.
Hi guys Pat the plumber here and in this video we're gonna go through a step-by-step process on what I do when I get called out for a service call for no hot water on a gas-fired water heater. So, let's get started. ​
The first step is doing a quick visual inspection checking for water at the base of the tank, and if the status light is blinking on the gas control valve. I will go over status light error codes later in  the video. 

  • Remove the panel concealing the burner door and sight glass. 
  • Look through the sight glass to see if the pilot is lit.  
  • If the pilot is lit and there's no status light blinking test the thermal piles voltage to see if it falls into spec. 
  • If the thermo-pile test fails, replace a thermo-pile.
  • If the test passes, replace the gas control valve; and 
  • If the pilot flame is out, we can move on to relighting the pilot. Before lighting the pilot, it is best to confirm that there's a gas supply to the residence. An easy way is checking another gas appliance such as a fireplace or stove.
  • If there's no gas supply check the storage tank or if it's a municipal supplied source, check the gas meter if this valve is in a horizontal position with a pin or lock through the hole, someone wasn't paying their bills and the gas supplier shut off the gas to the residence. 

Now that we've confirmed a gas supply to the residence:
  • Check to see if the gas valve to the appliance is in the on position.
  • The handle parallel to the piping is on and perpendicular is off to spark the igniter a few times to ensure that it is sparking properly and turn the gas control knob to pilot. 
  • Depress the knob and immediately spark the igniter.
  • Once the pilot is lit continue to hold down the nog for roughly one minute and the status light starts to blink your gas.
  • Control may give you an error code at this time. One flash every three seconds is normal operation. 
  • If the pilot goes out after you release the knob, take the following steps on this device. This is a re-settable thermal switch.
  • If the combustion chamber gets too hot, this device trips in one strip the pilot won't stay lit. 
  • To reset lightly push on the center button. If it clicks you know what has been tripped and you can now try to relate the pilot as per previous instructions.
  • If a trip thermal switch was the issue, the most common causes are lack of combustion air or an obstruction. 
  • Exhaust inspect the intake screen at the base of the water year. 
  • If Clau to vacuum away the dust, inspect the baffle underneath the draft hood to ensure that it is installed correctly. They're commonly misaligned due to transport. 
  • If misaligned, it could cause the exhaust not to escape.
  • Properly use caution when inspecting the baffle.
  • Make sure that the water heater is off and has had time to cool as the exhaust system can get extremely hot. 
  • If the pilot didn't stay lit after resetting, the thermal switch inspected the wiring making sure that there are no breaks or loose connections.
  • Next is bypassing the thermal switch, running a jumper wire from connection to connection or placing a metal bit across the connections as I've done here.
  • Try relating the water heater, and if it stays lit you know the thermal switch is faulty and requires a replacement. This jumper is just for testing purposes only and the water heater should never be run with this in place the thermal switch is a safety device and should be replaced if faulty.
  • If the pilot flame still won't stay lit, at this point it's time to test the thermal piles voltage. If the test fails, replace the thermal pile. If the test passes, replace the gas control valve.

I'll have video links at the end of this video and add a test and replace the thermal file as well as how to replace the gas control valve. 

  • If checking for error codes, remember one flash every three seconds is normal operation. Two flashes is a weak thermo-pile voltage and should be confirmed with a voltage.
  • Test and four five and seven flashes are issues with the gas control valve and require it to be replaced.

Well guys I hope this video got you in the right direction and like always if this video helped you out liking commenting subscribing is always greatly appreciated till next time. 

No Hot Water: Water Heater Troubleshooting 
By: Pros DIY
Retrieved from:
youtube.com/watch?v=_XYCVgsPu1U
0 Comments



Leave a Reply.

    RSS Feed

Home

Services

About

Contact

Comfort Plus Chicago Logo
CHICAGO, IL LOCATION
Comfort Plus Chicago
6351 W. Montrose Ave. Ste. #105
Chicago, IL 60634
312-471-0588​
NAPERVILLE, IL LOCATION
​Comfort Plus Chicago
115 E Ogden Ave Ste 105
Naperville, IL 60563
312-471-0588
SKOKIE, IL LOCATION
​Comfort Plus Chicago
4957 Oakton St
Skokie, IL 60077
312-471-0588
© 2020 Comfort Plus Chicago, All rights reserved.
Privacy Policy